IRO Model Specifications

Model:
IRO1 S/D IRO2 S/D IRO3 S/D IRO4 S/D IRO5 S/D IRO6 S/D
Performance:
Projected Rejection
>96%
>96% >96% >96% >96% >96%
Initial Production (GPD)* 2300 4600 6900 9200 11500 13800
Product Flow (GPM)* 1.5 3 4.5 6 7.5 9
Recovery Rate 50-75 % 50-75 % 50-75 % 50-75 % 50-75 % 50-75 %
Electrical - NOTE: The only difference between models S and D is the control panel and Electrical specs
All "S" models
Single Phase** 220V 13.5 Maximum Amps
Pump Horse Power 1.5
All "D" models
Three Phase** 220V 7.5 Maximum Amps
Pump Horse Power 1.5
Membranes:
Size (inches) 4 x40 4 x 40 4 x40 4 x40 4 x40 4 x 40
Quantity 1 2 3 4 5 6
Type Thin Film Composite Thin Film Composite Thin Film Composite Thin Film Composite Thin Film Composite Thin Film Composite
Feed Water Requirements IRO1 S/D IRO2 S/D IRO3 S/D IRO4 S/D IRO5 S/D IRO6 S/D
Max Free Chlorine <0.1 <0.1 <0.1 <0.1 <0.1 <0.1
Temperature Range 33-113 degrees F (1-45 degrees C)
Operating pH Range 4-11 4-11 4-11 4-11 4-11 4-11
Cleaning pH Range 2.0 - 11.5 2.0 - 11.5 2.0 - 11.5 2.0 - 11.5 2.0 - 11.5 2.0 - 11.5
Prefiltration 5 micron 5 micron 5 micron 5 micron 5 micron 5 micron
Pressure Feed Range (PSIG) 20-80 20-80 20-80 20-80 20-80 20-80
Max Fouling Index (SDI) <3 <3 <3 <3 <3 <3
Langelier Saturation Index <0 <0 <0 <0 <0 <0
Dimensions
Connections Inlet/Outlet/Drain 1" FPT
H x W x D (inches) 72 x 24 x 35
Approx Shipping Weight (lbs) 492 512 542 567 592 622

* Product flow rate varies with temperature. All model capacities are rated at 77 degrees F (25 C) with feed water of 1500 mg/L NaCl @ 200 PSI and pH of 7.5
** 208V and 440V are also available




Here are other AmeriWater RO systems:

CRO cabinet style RO system
for applications requiring from 300-2,000 GPD

Custom designed systems
for applications larger than 15,000 GPD





Optional maintenance program
Save energy, time and money while keeping your operating costs low with this simple and easy maintenance program. It lets you economically keep a spare set of components on hand. Depending on your needs this could include…

  • spare membrane(s)
  • PT401 anti-scalant liquid
  • carbon pack(s)
  • deionizer resin pack(s)
  • particulate filter(s)

When your components are exhausted, remove them and send the exhausted set by parcel to AmeriWater for replenishing.

Service is no problem
AmeriWater RO's have been designed so that any component can be easily replaced in minutes. If you have a service problem, just remove the component and call AmeriWater. Within 24 hours you'll receive a new component.

24 hour hotline
Working three shifts and weekends? Don't worry, AmeriWater is there to support you. If you have an emergency, call our toll-free 24 hour hotline.

 




AmeriWater

1303 Stanley Avenue
Dayton, Ohio 45404
Phone: 937-461-8833
Phone: 800-535-5585
Fax: 937-461-1988

e-mail: watertech@ameriwater.com

Industrial | Services | Accessories
Silex Deionizers | Reverse Osmosis
PrintWater Systems | Cooling Tower Filtration
Water Treaters | Heavy Metal Removal
Deionizer Tank Exchange | EDM Resin Service
AmeriWater Home | Ask a Question

Contents Copyright 1999-2004 AmeriWater